WRES-NH3LB DC1500V-630A

This series of fuses are suitable for short circuit and overload protection of electric vehicle drive power system, power conversion system, energy storage and power system, variable
frequency controller, charging pile, and other vehicle devices and equipment in lines with DC rated voltage up to 1500V and rated current up to 630A. The rated breaking capacity is up to 250kA. The fuses conform to the national standard GB/T13539.7 and the International Electrotechnical Commission Standard IEC60269-7.

Application

This series of fuses are suitable for short circuit and overload protection of electric vehicle drive power system, power conversion system, energy storage and power system, variable
frequency controller, charging pile, and other vehicle devices and equipment in lines with DC rated voltage up to 1500V and rated current up to 630A. The rated breaking capacity is up to 250kA. The fuses conform to the national standard GB/T13539.7 and the International Electrotechnical Commission Standard IEC60269-7.

 

Normal working conditions

1、The effect of current

The upper limit of ambient air temperature should not exceed 90℃; the lower limit of ambient air temperature should not be lower than -50℃; the altitude of the installation site should not exceed 2000m (if you want to exceed this 2000m, you need to indicate the requirements, and the company can design and develop according to customer requirements).

fuse link derating table for installation

Installation altitudem Percentage of current derating (A) Percentage of Insulation performance derating(V)
2000 100% 100%
3000 95% 90%
4000 90% 80%
5000 85% 70%

For example: the rated current is 1800A and the installation site altitude is 5000m, the actual selection is 1800*85%≈1530A.

2、The effect of Voltage

The rated voltage of photovoltaic fuses does not need to be derated for installation altitudes not exceeding 5000m, but it is affected by air pressure on the power frequency withstand voltage and insulation performance to a certain extent. The test voltage of DC 1001-1500V is 3820V, and Our products reach at least 6000V, so here is no need to consider.

3、The effect of temperature

The following figure shows a typical curve of the influence of ambient temperature on current carrying capacity:

The Effect Of Temperature

For example: In some applications, the ambient temperature is 20°C, and the rated current of the photovoltaic (aBat type) fuse is selected as 63A. Now, the above-mentioned fuse is often used in a high temperature environment of 70 ℃, then the fuse must be derated. The environmental bearing capacity curve A in the figure shows that the percentage of the rated operating value at 70°C is 0.78, that is to say, the rated current value of the fuse should be reselected:

图片

Choose 80A according to the standard current level of the fuse

Use category

“aBat” is Fast DC fuse for new energy protection.

Structural features

The variable cross-section melt made of silver flakes is encapsulated in a high-strength melt tube. The melt tube is filled with chemically treated high-purity quartz sand and special treatment chemicals as the arc extinguishing medium. The welding and the contacts are firmly electrically connected.

The main technical parameters

Figure 1

Model of fuse Rated voltage Rated Current(A) overall dimension/size(mm)
WRES-NH3LB DC1500V 100125160200250300315350400450500550630 Figure 1

Microswitch Description

Microswitch Description

During the normal operation of the fuse link, 1 and 3 are connected, and 1 and 2 are disconnected. When the fuse link is fused, the indicator acts, 1 and 3 are disconnected, and 1 and 2 are connected, so as to achieve the function of remote monitoring, and remind the electrician that the fuse is fused, please replace it in time.

 

Fuse cold resistance and power dissipation

Fuse type Rated Voltage Rated Current(A) I²T (A²S) 0.5In(W) 0.8In(W) 1.0In(W) Dimensions/Size(mm)
ABat Pre-arcinge Total
WRES – NH3LB DC1500V 100 1140 5800 11 23 43 Figure 1
125 2100 10400 12 29 53
160 3700 18400 16 36 67
200 6300 31600 20 44 81
250 13000 61500 21 47 86
300 21800 109300 26 56 99
315 22900 115000 27 59 110
350 33000 165000 28 61 112
400 57000 285000 29 64 114
450 74000 349000 32 71 133
500 91200 422000 36 78 143
550 107000 477000 41 90 162
630 164000 737000 43 95 181

Melting characteristic curve