WRPV-30
- Standard: IEC60269-6,UL248-19,GB/T13539.6
- Breakingcapacity: 33kA
- Construction: Cylindrincal
- With Forced Arc Extinguishing
Features
- Standard: IEC60269-6,UL248-19,GB/T13539.6
- Breakingcapacity: 33kA
- Construction: Cylindrincal
- With Forced Arc Extinguishing
Dimensions (mm)

Fuse cold-state resistance andpower loss
| Product Model |
Rated current(A) |
Watts Loss (W) |
Energy Integralsl²t(A²s) | |
| Pre-Arcing | Total at 1000V | |||
| WRPV- 30 |
1 | 1.30 | 1.1 | 3.9 |
| 2 | 1.36 | 1.5 | 5.2 | |
| 3 | 1.42 | 2.4 | 8.6 | |
| 4 | 1.58 | 2.9 | 11.4 | |
| 5 | 1.83 | 6.7 | 25.7 | |
| 6 | 1.84 | 10.5 | 40 | |
| 8 | 1.86 | 15.2 | 57 | |
| 10 | 2.08 | 20 | 92 | |
| 12 | 2.62 | 30.4 | 143 | |
| 15 | 2.95 | 45.6 | 205 | |
| 20 | 3.12 | 79.8 | 366 | |
| 25 | 3.46 | 114 | 599 | |
| 30 | 3.78 | 143 | 713 | |
| 32 | 3.95 | 148 | 722 | |
Technical Parameters
| Fuse Link Type gPV |
Rated Voltage(V) | Rated current(A) | Dimensions(mm) | Watts Loss(W) |
| WRPV-30 | DC1000V | 1,2,3,4,5,6,8,10,12,15,16,20,25,30,32 | 10×38 | ≤4 |
Technical Parameters
| Fuse Holder Type | Fuse link size | Rated Voltage(V) | Rated current(A) | Watts Loss(W) |
| WRPV-30D | 10×38 | 1000Vdc | 32A | 4W |